How to choose actuator torque by valve size
Torque is an essential parameter indicating the power to drive the valve open or close.It depends on the valve size,working pressure,etc and is measured by factory test.
Grat offers the table of size and torque as a solution.
           Type EA20 EA50 EA100 EA200 EA400 EA600 EA1000 EA1500 EA2000
 Characteristics
Output torque 20NM 50NM 100NM 200NM 400NM 600NM 1000NM 1500NM 2000NM
Action time(S) 10/20 4/10
20/60
4/7
15/30/60
6/15
30/60
6/15
30/60
45 15/30 48 60/75
Gyration angle 0-90°
0-360°
0-90°
0-360°
0-90°
0-360°
0-90° 0-90° 0-90° 0-90° 0-90° 0-90°
Motor power
(W)
AC220V 6 10 25 40 90 90 120 140 140
AC380V   ------- 6 15 30 40 40 90 100  --------
DC24V 8 13 25 35 70 70 --------- --------- ----------
Rated current(A) AC220V 0.16 0.16 0.32 0.35 0.54 0.64 0.96 0.98 1.03
AC380V --------- 0.07 0.1 0.15 0.29 0.29 0.45 0.46  ---------
DC24V 0.7 1.28 2.03 3.57 5.13 3.04 --------- --------  --------
Weight(Kg) 1.2 2.5 3.5 8 8.5 9 17 18 20
For ball valve DN15-25 DN15-40 DN50-
65
DN80-
125
DN125-200 DN200-
300
-------- -------- ---------
For butterfly valve DN32-40 DN50-80 DN80-
125
DN150-
200
DN200-300 DN300-
450
DN400-
500
DN500-
600
DN600-
800
Power   AC 220V±10% 50HZ/60HZ,  AC 380V±10% 50HZ/60HZ, DC24V
Insulation resistance   100MΩ/500VDC 
Anti-pressure level   1500VAC 1Min
Protection level   IP67(It is no leakage in water about 20 meters deep)
Limited component   Power-driven: Fully open and close, limit switch.
  Manual: Mechanical stopper.
Protector   Overheat protector(self-recovery)
Installation position   Any direction from 0 to 360 degree
Electrical connection   M20*1.5 Waterproof cable connection, power wire, signal wire
Ambient Temp.   -30ºC--60ºC
 
 






Preview : New Micro Flow Regulation Technology Application--Equator Regulating Valve


Next : Control valve technology—How to choose low-temperature control valves

APPLICATION

Leading manufacturer of industrial automation equipment

PRODUCTS
CONTACT US